Comparison of Reactor Type for Pollution Control by Using the Pulsed Corona Discharge

  • Seok, Dong Chan
  • Jung, Yong Ho
  • Lho, Taihyeop
  • Chung, Kyu-Sun
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

We investigated efficiency of removal of NO and NOx for applied voltage, repetition frequency and energy according to reactor type (wire-plate and wire-cylinder type reactor). Characteristics of Reactor type by pulsed corona discharge could be analyzed through these Results, Because it is very difficult to measure the conduction current for calculation of energy transferred into the reactor in the corona discharge, conduction current was obtained indirectly and the necessary energy for removal of NO and NOx was calculated from conduction current. Removal efficiency of NO and NOx for control variable (applied voltage, pulse repetition frequency, energy transferred into the reactor and removed quantity etc) in the wire-cylinder type reactor was higher than that in the wire-plate type reactor.

키워드

NONTHERMAL PLASMA REACTORNOX REMOVALGENERATION
제목
Comparison of Reactor Type for Pollution Control by Using the Pulsed Corona Discharge
저자
Seok, Dong ChanJung, Yong HoLho, TaihyeopChung, Kyu-Sun
DOI
10.13182/FST09-A7016
발행일
2009-02
유형
Article; Proceedings Paper
저널명
Fusion Science and Technology
55
2T
페이지
213 ~ 217