프리캐스트 콘크리트 보-기둥 접합부의 이력거동 및 내진성능

Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections

초록

Five half-scale beam-to-column connections in a precast concrete frame were tested with cyclic loading that simulated earthquake-type motions. Five half -scale interior beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including one monolithic specimen and four precast specimens. Variables included the detailing used at the joint to achieve a structural continuity of the beam reinforcement, and the type of special reinforcement in the connection (whether ECC or transverse reinforcement). The specimen design followed the strong-column-weak-beam concept. The beam reinforcement was purposely designed and detailed to develop plastic hinges at the beam and to impose large inelastic shear force demands into the joint. The joint performance was evaluated on the basis of connection strength, stiffness, energy dissipation, and drift capacity. From the test results, the plastic hinges at the beam controlled the specimen failure. In general, the performance of the beam-to-column connections was satisfactory. The joint strength was 1.15 times of that expected for monolithic reinforced concrete construction. The specimen behavior was ductile due to tensile deformability by ECC and the yielding steel plate, while the strength was nearly constant up to a drift of 3.5 percent.

키워드

보-기둥 접합부철골연결재섬유보강콘크리트내진성능반복하중 실험Beam-to-columnSteel plate connectionEngineered cementitious compositeSeismic performanceCyclic load testBeam-to-columnSteel plate connectionEngineered cementitious compositeSeismic performanceCyclic load test
제목
프리캐스트 콘크리트 보-기둥 접합부의 이력거동 및 내진성능
제목 (타언어)
Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections
저자
최현기최윤철최창식
DOI
10.5000/EESK.2010.14.4.061
발행일
2010-08
저널명
한국지진공학회논문집
14
4
페이지
61 ~ 71