Feasibility of Applying Fourier Transform Electrochemical Impedance Spectroscopy in Fast Cyclic Square Wave Voltammetry for theIn VivoMeasurement of Neurotransmitters

  • Park, Cheonho
  • Hwang, Sangmun
  • Kang, Yumin
  • Sim, Jeongeun
  • Cho, Hyun U.
  • ... Jang, Dong Pyo
  • 외 6명
Citations

WEB OF SCIENCE

15
Citations

SCOPUS

15

초록

We previously reported on the use of fast cyclic square wave voltammetry (FCSWV) as a new voltammetric technique. Fourier transform electrochemical impedance spectroscopy (FTEIS) has recently been utilized to provide information that enables a detailed analytical description of an electrified interface. In this study, we report on attempts to combine FTEIS with FCSWV (FTEIS-FCSWV) and demonstrate the feasibility of FTEIS-FCSWV in thein vivodetection of neurotransmitters, thus giving a new type of electrochemical impedance information such as biofouling on the electrode surface. From FTEIS-FCSWV, three new equivalent circuit element voltammograms, consisting of charge-transfer resistance (Rct), solution-resistance (Rs), and double-layer capacitance (Cdl) voltammograms were constructed and investigated in the phasic changes in dopamine (DA) concentrations. As a result, allRct,Rs, andCdlvoltammograms showed different DA redox patterns and linear trends for the DA concentration (R2> 0.99). Furthermore, theRctvoltammogram in FTEIS-FCSWV showed lower limit of detection (21.6 ± 15.8 nM) than FSCV (35.8 ± 17.4 nM). FTEIS-FCSWV also showed significantly lower prediction errors than FSCV in selectivity evaluations of unknown mixtures of catecholamines. Finally,Cdlfrom FTEIS-FCSWV showed a significant relationship with fouling effect on the electrode surface by showing decreased DA sensitivity in both flow injection analysis experiment (r= 0.986) andin vivoexperiments. Overall, this study demonstrates the feasibility of FTEIS-FCSWV, which could offer a new type of neurochemical spectroscopic information concerning electrochemical monitoring of neurotransmitters in the brain, and the ability to estimate the degree of sensitivity loss caused by biofouling on the electrode surface.

키워드

304-STAINLESS-STEEL DISSOLUTION PROCESSDOUBLE-LAYER CAPACITANCEELECTRODE
제목
Feasibility of Applying Fourier Transform Electrochemical Impedance Spectroscopy in Fast Cyclic Square Wave Voltammetry for theIn VivoMeasurement of Neurotransmitters
저자
Park, CheonhoHwang, SangmunKang, YuminSim, JeongeunCho, Hyun U.Oh, YoonbaeShin, HojinKim, Do HyoungBlaha, Charles D.Bennet, Kevin E.Lee, Kendall H.Jang, Dong Pyo
DOI
10.1021/acs.analchem.1c02308
발행일
2021-12
유형
Article
저널명
Analytical Chemistry
93
48
페이지
15861 ~ 15869