Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy

  • Lee, Soo Min
  • Choi, Chansoo
  • Choi, Ji Won
  • Min, Chul Hee
  • Ko, Seulki
  • ... Kim, Chan Hyeong
  • 외 2명
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

3

초록

To investigate the impact of the recently released pediatric reference voxel phantoms (0-, 1-, 5-, 10-, 15-year-old males and females) of the International Commission on Radiological Protection (ICRP) on organ dose estimates for radioactive iodine (RAI) treatment in pediatric patients, we calculated and analyzed pediatric-specific iodine-131 S values (rT ← thyroid) for the 30 radiosensitive organs by conducting Monte Carlo simulations using the Geant4. The gender dependency in the S values was frequently seen for the 15-year-old phantoms with higher S values of female than male. In addition, the age dependency in the S values was observed for most target organs; that is, the S values tend to decrease for older ages (e.g., ∼120 times for the gonads between the adult and newborn) due mainly to the inter-organ distances generally longer for older ages. Moreover, we observed that the iodine-131 S values tend to be significantly greater by up to ∼145.5 times than those of the stylized phantoms that have been widely used for organ dose estimates of pediatric RAI patients. We believe that the pediatric-specific iodine-131 S values (rT ← thyroid) of the ICRP pediatric reference voxel phantoms should be beneficial to improve the dosimetry of pediatric RAI patients.

키워드

Iodine-131S valuesICRP pediatric reference phantomsMonte Carlo simulationPediatric patientsInternal dosimetry
제목
Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy
저자
Lee, Soo MinChoi, ChansooChoi, Ji WonMin, Chul HeeKo, SeulkiShin, BanghoKim, Chan HyeongYeom, Yeon Soo
DOI
10.1016/j.net.2024.01.033
발행일
2024-07
유형
Article
저널명
Nuclear Engineering and Technology
56
6
페이지
2247 ~ 2257