Validation of magnetic resonance velocimetry for mean velocity measurements of turbulent flows in a circular pipe

  • Lee, Jeesoo
  • Ko, Seungbin
  • Cho, Jee-Hyun
  • Song, Simon
Citations

WEB OF SCIENCE

15
Citations

SCOPUS

15

초록

Magnetic resonance velocimetry (MRV) is a versatile flow visualization technique that has been utilized for medical applications. Recently, MRV has been used to visualize engineering flows, but most engineers are still unfamiliar with the technique. In this paper, we introduce the basic principles and experimental configurations of MRV in detail and evaluate the accuracy of MRV applied to measure the mean velocity fields of turbulent flows in a circular pipe. A Philips Achieva 3.0 T Tx MRI scanner is used to provide a magnetic field and acquire resonance signals for flow visualization. Fully developed turbulent flows with Reynolds numbers of 6800, 9900 and 19400 were measured, and the axial mean velocity vectors were obtained with a spatial resolution of 0.5 mm for the three directions. Results show that the mean velocity profiles are in good agreement with reference data sets when properly scaled in both the inner and outer layers.

키워드

Flow visualizationMagnetic resonance velocimetryCircular pipe flowPhase-contrast MRIPHASE-CONTRAST MRIIN-VITROQUANTIFICATIONANGIOGRAPHY
제목
Validation of magnetic resonance velocimetry for mean velocity measurements of turbulent flows in a circular pipe
저자
Lee, JeesooKo, SeungbinCho, Jee-HyunSong, Simon
DOI
10.1007/s12206-017-0226-x
발행일
2017-03
유형
Article
저널명
Journal of Mechanical Science and Technology
31
3
페이지
1275 ~ 1282