Optimal boundary detection method and window settings for coronary atherosclerotic plaque volume analysis in coronary computed tomography angiography: comparison with intravascular ultrasound

  • Heo, Ran; 
  • Park, Hyung-Bok; 
  • Lee, Byoung Kwon; 
  • Shin, Sanghoon; 
  • Arsanjani, Reza; 
  • 외 2명
Citations

WEB OF SCIENCE

24
Citations

SCOPUS

25

초록

Objective: To evaluate optimal methodology for quantitative plaque volume analysis by coronary CT angiography (QCT). Methods: Fifty-one coronary artery segments were evaluated and contour measurements based on two different methods [(1) no gap, or (2) fixed 0.3-mm gap between inner and outer boundary] were compared with intravascular ultrasound (IVUS). In addition, three different window width (WW) and level (WL) settings [fixed (740/220) Hounsfield unit (HU), adjusted (155 % and 65 % of mean luminal intensity of the segment, and aorta adjusted (155 % and 65 % of mean luminal intensity of central aorta)] were used for semiautomated plaque volume analysis. Results: For boundary detection, the no gap method led to underestimation compared with IVUS (105.4 ± 82.3 vs. 136.1 ± 72.8 mm³, p < 0.001), while fixed 0.3-mm gap showed no difference between IVUS and QCT (136.1 ± 72.8 vs. 139.8 ± 93.9 mm³, p = 0.50). Comparison of the three different window settings demonstrated that the aorta adjusted setting underestimated (120.5 ± 74.3 vs. 136.1 ± 72.8 mm³, p = 0.003), while fixed setting showed the least mean difference compared with IVUS (3.8 ± 39.8 mm³, p = 0.50). Conclusion: For plaque volumetric assessment, optimal results were obtained with fixed 0.3-mm gap with fixed HU setting (740/220). Key points: • Quantitative plaque volume analysis by coronary CT angiography has recently emerged. • Different boundary detection methods and window width and level settings were evaluated. • Fixed 0.3-mm gap with fixed HU setting (740/220) afforded optimal results.

키워드

Coronary CT angiography; Quantitative plaque volume analysis; Boundary detection; Window settings; Intravascular ultrasound; CT ANGIOGRAPHY; ARTERY-DISEASE; VIRTUAL HISTOLOGY; NATURAL-HISTORY; QUANTIFICATION; MORPHOLOGY; ACCURACY; LESIONS; VESSEL; STATIN
제목
Optimal boundary detection method and window settings for coronary atherosclerotic plaque volume analysis in coronary computed tomography angiography: comparison with intravascular ultrasound
저자
Heo, Ran; Park, Hyung-Bok; Lee, Byoung Kwon; Shin, Sanghoon; Arsanjani, Reza; Min, James K.; Chang, Hyuk-Jae
DOI
10.1007/s00330-015-4121-5
발행일
2016-09
유형
정기학술지(Article(Perspective Article포함))
저널명
European Radiology
권
26
호
9
페이지
3190 ~ 3198