암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절

pH Control of Feed Water for HRSG with Additional Injection of NH3

초록

This study was conducted on combined cycle power plant consisting of HRSG with integral deaerator type to avoid tube failures of low pressure evaporator tubes. Based on the observation of pH variation at the discharge of boiler feed water pump by continuous pH measurement for a period of time, it was identified that pH of feed water is getting reduced as ammonia is distributed into vapor and liquid depending on the distribution ratio of ammonia in the LP drum after the deaerator. To solve this problem, the counterplan was prepared by reexamination of ammonia injection point and quantity. In conclusion, it was accomplished that 9.2~9.6 is the optimized pH range for boiler feed water by arranging additional piping for ammonia to inject directly to LP drum.

키워드

복합화력발전소배열회수보일러탈기기-저압드럼 일체형수소이온 농도암모니아 주입설비 HRSGIntegral Deaerator TypepH
제목
암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절
제목 (타언어)
pH Control of Feed Water for HRSG with Additional Injection of NH3
저자
목용강문승재이재헌
발행일
2015-06
유형
정기학술지(Article(Perspective Article포함))
저널명
플랜트 저널
11
2
페이지
32 ~ 38