0초록
In this study, we tried to define the erosion-corrosion behavior together with the resulting effects on a pipe that is a part of a feed water circulation system according to the pipe size and hot feed water environment. An erosioncorrosion analysis was performed through the Hayduk and Minhas model based on the chemical reaction between iron and oxygen, an essential corrosive factor. The erosion-corrosion rate against the pipe diameter and feed water temperature was then evaluated by means of finite element analysis using ABAQUS. As shown in the results, the feed water temperature was the main factor influencing the erosion-corrosion rate; in particular, it was expected that the thickness of 316 stainless steel would decrease by 2.59 μm every year in a hot water environment at 290°C.
키워드
- 제목
- 고온 급수에 의한 파워 플랜트 배관 침식-부식 거동
- 제목 (타언어)
- Erosion-corrosion behavior of power plant pipe caused by hot feed water
- 저자
- Bang, Sung-Ho; Lee, Jin-Won; Kim, Tae-Won
- 발행일
- 2013-06
- 유형
- Article
- 저널명
- 대한기계학회논문집 A
- 권
- 37
- 호
- 6
- 페이지
- 739 ~ 745