상세 보기
외부 보 기둥 접합부에 정착된 고강도 대구경 확대머리철근의 정착강도
Anchorage Strengths of High-Strength Large-Diameter Headed Bars in Exterior Beam-Column Joint
- 정형석;
- 김정엽;
- 최창식
초록
In this research, the development length of headed bar and the transverse reinforcement ratio of the beam column joint on the seismic behavior of exterior beam column joints was experimentally investigated. Four beam column joints specimens were tested with the large dimeter headed bars. The variables for this study were the side clear cover thickness, transverse reinforcement ratio and failure type. The test results showed enough anchorage capacity of large diameter headed bars and ductile behavior of exterior beam column joints.
- 제목
- 외부 보 기둥 접합부에 정착된 고강도 대구경 확대머리철근의 정착강도
- 제목 (타언어)
- Anchorage Strengths of High-Strength Large-Diameter Headed Bars in Exterior Beam-Column Joint
- 저자
- 정형석; 김정엽; 최창식
- 발행일
- 2016-05
- 유형
- Proceeding
- 저널명
- 한국콘크리트학회 학술대회 논문집
- 권
- 28
- 호
- 1
- 페이지
- 755 ~ 756