초록

The metallographic examination and hardness measurements were conducted for the rotor of the 500 MW tandem steam turbine of Unit 4 in Dangjin Thermal Power Plants at the locations of steam inlet where the high temperature steams pass; high and intermediate pressure turbines. Creep cavity and degradation levels of optical micrographs of them are observed. The remaining life time of 201,523h for the rotor of the 500 MW tandem steam turbine of Unit 4 in Dangjin Thermal Power Plants was determined by the results of the inspection.