The effect of sound field characteristics on floor impact sound measurements using a heavy/soft impact source

  • Yoo, Seung Yup
  • Lee, Pyoung Jik
  • Jeon, Jin Yong
Citations

SCOPUS

0

초록

In this study, the spatial distribution of heavy-weight impact sound pressure levels was investigated by field measurements using the heavy/soft impact source, which is specified as a standard heavy-weight impact source in 140-11. The results showed that the vertical and horizontal distribution of measured sound pressure levels showed a significant room mode at low frequencies. Among the existing standards for measurement of a heavy-weight impact sound, KS F 2810-2 and JIS A 1440-2 provide a good estimate of the room average sound pressure level for floating floor with respect to a low bias error and 95% confidence interval. The guideline for measurement of a heavy-weight impact source was proposed in order to complement the limitations of KS F 2810-2 and JIS A 1440-2.

키워드

Confidence intervalField measurementFloating floorFloor-impact soundHorizontal distributionImpact soundLow biasLow frequencySound pressure levelAcoustic fieldsAcoustic variables controlAcoustic wave transmissionAcoustic wavesArchitectural acousticsFire alarm systemsFloorsAcoustic variables measurement
제목
The effect of sound field characteristics on floor impact sound measurements using a heavy/soft impact source