상세 보기
초록
In this study, the spatial distribution of heavy-weight impact sound pressure levels was investigated by field measurements using the heavy/soft impact source, which is specified as a standard heavy-weight impact source in 140-11. The results showed that the vertical and horizontal distribution of measured sound pressure levels showed a significant room mode at low frequencies. Among the existing standards for measurement of a heavy-weight impact sound, KS F 2810-2 and JIS A 1440-2 provide a good estimate of the room average sound pressure level for floating floor with respect to a low bias error and 95% confidence interval. The guideline for measurement of a heavy-weight impact source was proposed in order to complement the limitations of KS F 2810-2 and JIS A 1440-2.
키워드
- 제목
- The effect of sound field characteristics on floor impact sound measurements using a heavy/soft impact source
- 저자
- Yoo, Seung Yup; Lee, Pyoung Jik; Jeon, Jin Yong
- 발행일
- 2009-10
- 유형
- Conference Paper
- 저널명
- 8th European Conference on Noise Control 2009, EURONOISE 2009 - Proceedings of the Institute of Acoustics
- 권
- 31
- 호
- PART 3
- 페이지
- 3427 ~ 3430