강교용 박스거더의 용접예열 온도 선정에 관한 연구

Determination of Preheating Temperature for Box Girder Welding

초록

This study analyzed causes and status of cracks to suggest preventives for welding cracks generated on fillet welding zone of atmosphere corrosion resisting steel box girder. Penetrant testing, a sort of non-destructive testing, was conducted for inspection of crack status on welding zone. As a result of test, welding cracks were found on the point of start, center and end to fillet welding zone of 32 mm-thickness. The result of carbon equivalent composition of materials was 0.452%. According to welding specification, to preheat prevent welding crack, preheat temperature of 100∼200∘C should be kept before welding execution. It was failed to keep preheat temperature because it had been executed on winter season and the structure of box girder had wide heat transfer area. As a result of examination of time varying preheating temperature of 32mm-thickness material, it was understood that preheat temperature of above 230∘C on both 130mm-long sides of welded joint can prevent welding crack.

키워드

box girdercarbon equivalentpreheatingwelding crack
제목
강교용 박스거더의 용접예열 온도 선정에 관한 연구
제목 (타언어)
Determination of Preheating Temperature for Box Girder Welding
저자
조재훈문승재유호선
발행일
2011-03
유형
정기 학술지(letter(letters to the editor))
저널명
플랜트 저널
7
1
페이지
49 ~ 55