Determination of azelastine in human plasma by validated liquid chromatography coupled to tandom mass spectrometry (LC-ESI/MS/MS) for the clinical studies

  • Park, Yoo-Sin
  • Kim, Shin-Hee
  • Kim, Young-Jae
  • Yang, Seok-Chul
  • Lee, Min-Ho
  • 외 2명
Citations

SCOPUS

26

초록

A liquid chromatography coupled to tandem mass spectrometry (LC-ESI/MS/MS) was validated to determine azelastine in human plasma. Azelastine and internal standard (IS, clomipramine) were separated using a mobile phase of acetonitrile:(5 mM)-ammonium acetate solution (70:30, v/v, pH=6.4) with flow rate of 0.25 mL/min over YMC C8 column. One mL of plasma was extracted by n-hexane: 2-propanol (97:3, v/v) and then injected into HPLC system after reconstitution by acetonitrile: (5 mM)-ammonium acetate (1:1, v/v) solution. Detection was carried out on API5000 MS system by multiple reactions monitoring mode. The ionization was optimized using ESI (+) and selectivity was achieved at m/z 382.2→112.2 for azelastine and m/z 315.3→228.0 for IS. Total run-time (<2.0 min) and linearity (10 (LLOQ) ~5000 pg/mL) were good. No endogenous compounds were found around the retention time. The inter- and intra-day precision and accuracy were 4.13~17.91% and 87.57~109.70%, respectively. This validated method was successfully applied to a bioequivalence study in 23 healthy Korean male volunteers from the blood samples taken up to 96 h after orally administered 2 tablets of 1 mg of reference and test formulations of azelastine in a double-blind, randomized, cross-over design. The mean peak plasma concentrations (Cmax ± SD) of 1.02 ± 0.37 and 1.10 ± 0.43 ng/mL were reached at 5.9 and 5.6 h for reference and test azelastine, respectively. The mean total area under the curve (AUC0-infinity) were 25.96 ± 10.84 and 28.24 ± 11.09 ng•h/mL for reference and test formulations, respectively. The reference and test azelastine formulations can be considered bioequivalent from the obtained pharmacokinetics by LC-ESI/MS/MS.

키워드

AzelastineBioequivalenceLC-ESI/MS/MSPharmacokinetics2 propanolacetonitrileammonium acetateazelastineclomipraminehexaneaccuracyadultarea under the curvearticlebioequivalenceblood samplingclinical trialcontrolled clinical trialcontrolled studycrossover proceduredouble blind proceduredrug blood leveldrug determinationdrug eliminationdrug half lifeflow ratehigh performance liquid chromatographyhumanhuman experimentmalemaximum plasma concentrationnormal humanrandomized controlled trialseparation techniquetandem mass spectrometrytime to maximum plasma concentrationvolunteer
제목
Determination of azelastine in human plasma by validated liquid chromatography coupled to tandom mass spectrometry (LC-ESI/MS/MS) for the clinical studies
저자
Park, Yoo-SinKim, Shin-HeeKim, Young-JaeYang, Seok-ChulLee, Min-HoShaw, Leslie M.Kang, Ju Seop
발행일
2010-06
유형
Article
저널명
International Journal of Biomedical Science
6
2
페이지
120 ~ 127