A study on DCGL determination and the classification of contaminated areas for preliminary decommission planning of KEPCO-NF nuclear fuel fabrication facility

  • Cho, Seo-Yeon
  • Kim, Yong-Soo
  • Park, Da-Won
  • Park, Chan-Jun
Citations

WEB OF SCIENCE

3
Citations

SCOPUS

5

초록

As a part of the preliminary decommissioning plan of KEPCO-NF fuel fabrication facility, DCGLs of three target radionuclides, 234U, 235U, and 238U, were derived using RESRAD-BUILD code and contaminated areas of the facility were classified based on contamination levels from the derived DCGLs. From code simulations, one-room modeling results showed that the grinding room in building #2 was the most restrictive (DCGLgross = 10493.01 Bq/m2). The DCGLgross results in contaminated areas from one-room modeling were slightly more conservative than three-room modeling. Prior to the code simulation, field survey and measurements conducted by each survey unit. For a conservative approach, the most restrictive DCGLgross in each survey unit was taken as a reference to classify the contaminated areas of the facility. Accordingly, seven rooms and 37 rooms in the nuclear-fuel buildings were classified as Class 1 and Class 2, respectively. As expected, fuel material handling and processing rooms such as the grinding room, sintering room, compressing room, and powder collecting room were included in the Class 1 area.

키워드

DCGLDecommissioningNuclear fuel fabrication facilityRESRAD-BUILDMARSSIMKOREA
제목
A study on DCGL determination and the classification of contaminated areas for preliminary decommission planning of KEPCO-NF nuclear fuel fabrication facility
저자
Cho, Seo-YeonKim, Yong-SooPark, Da-WonPark, Chan-Jun
DOI
10.1016/j.net.2019.06.012
발행일
2019-12
유형
Article
저널명
Nuclear Engineering and Technology
51
8
페이지
1951 ~ 1956