Influence of void on image quality of industrial SPECT

  • Park, Jang Guen
  • Jung, Seung-Hun
  • Kim, Jong Bum
  • Moon, Jinho
  • Kim, Chan Hyeong
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

Industrial single photon emission computed tomography (SPECT) is a promising technique to determine the dynamic behavior of industrial process media and has been developed in the Korea Atomic Energy Research Institute. The present study evaluated the influence of a void, which is presence in multiphase reactors of industrial process, on the image quality of an industrial SPECT. The results are very encouraging; that is, the performance of the industrial SPECT system is little influenced by the presence of a void, which means that industrial SPECT is an appropriate tool to estimate the dynamic characteristics of the process media in a water-air phase bubble column with a static gas sparger.

키워드

Gamma cameraSPECTPET PET/CTcoronary CT angiography (CTA)Inspection with gamma rays
제목
Influence of void on image quality of industrial SPECT
저자
Park, Jang GuenJung, Seung-HunKim, Jong Bum Moon, JinhoKim, Chan Hyeong
DOI
10.1088/1748-0221/8/12/P12011
발행일
2013-12
유형
Article
저널명
Journal of Instrumentation
8
페이지
1 ~ 12