연료전지 적용 액체식 제습공조시스템의 식물공장 연간 에너지소비 절감효과 분석
Annual energy performance of liquid desiccant air conditioning system with fuel cell in plant factory
- 임려화 ;
- 정재원
초록
This study compared the annual energy consumption of the heat pump-driven liquid desiccant (HPLD) system and the variable air volume (VAV) system in a plant factory. According to the simulation, the HPLD system can save 77.4% energy consumption than the VAV system. A 10 kW proton exchange membrane fuel cell (PEMFC) can meet 92% of electricity demand and 80.9% of heat demand in this plant factory. In addition, this plant factory can reduce 14.8% of the carbon dioxide emissions from the fuel cell and meet 7.1% of the daily water loss through the water from the fuel cell. At the same time, a 4.5 MWh battery energy storage system can cover the power storage of the plant factory.
- 제목
- 연료전지 적용 액체식 제습공조시스템의 식물공장 연간 에너지소비 절감효과 분석
- 제목 (타언어)
- Annual energy performance of liquid desiccant air conditioning system with fuel cell in plant factory
- 저자
- 임려화 ; 정재원
- 발행일
- 2021-05-14
- 학회명
- 한국생태환경건축학회 2021년도 춘계학술발표대회
- 개최지
- 서울과학기술대학교, 온라인 Zoom
- 개최국가
- 대한민국
- 학회 개최일
- 2021-05-14 ~ 2021-05-14