관성측정장치를 이용한 보행거리 측정 시스템 개발

Development of Gait Distance Measurement System Based on Inertial Measurement Units
  • 이기혁
  • 강신일
  • 조재성
  • 임도형
  • 이종실
  • ... 김인영

초록

In this paper, we present an inertial sensor-based gait distance measurement system using accelerometer, gyroscope, and magnetometer. To minimize offset and gain error of inertial sensors, we performed the calibration using the self-made calibration jig with 9 degrees of freedom. For measuring accurate gait distance, we used gradient descent algorithm to remove gravity error and used analysis of gait pattern to remove drift error. Finally, we measured a gait distance by double-integration of the error-removed acceleration data. To evaluate the performance of our system, we walked 10m in a straight line indoors to observe the improvement of removing error which compared un-calibrated to calibrated data. Also, the gait distance measured by the system was compared to the measurement of the Vicon motion capture system. The evaluation resulted in the improvement of 31.40±14.38%(mean±S.D.), 78.64±10.84% and 69.71±26.25% for x, y and z axis, respectively when walked in a straight line, and a root mean square error of 0.10m, 0.16m, and 0.12m for x, y and z axis, respectively when compared to the Vicon motion capture system.

키워드

Inertial Measurement UnitsGait distanceDouble-integrationAccelerometer
제목
관성측정장치를 이용한 보행거리 측정 시스템 개발
제목 (타언어)
Development of Gait Distance Measurement System Based on Inertial Measurement Units
저자
이기혁강신일조재성임도형이종실김인영
발행일
2015-05
저널명
재활복지공학회논문지
9
2
페이지
161 ~ 168