상세 보기
ATOM-MIRD Hybrid Voxel Model for Monte Carlo Calculations of Organ Doses: A Complement to a Physical Phantom
- Cho, Sungkoo;
- Choi, Sang Hyoun;
- Yi, Chul-Young;
- Kim, Chan Hyeong
Citations
WEB OF SCIENCE
0Citations
SCOPUS
0초록
In this study, a hybrid voxel model was constructed by combining the voxel model of the ATOM adult male phantom with the organ models of the MIRD5 mathematical phantom. The organ models of the mathematical phantom were successfully transferred to the hybrid model, replicating the sizes of the organs within a 3% difference. Consequently, a total of 14 main radiosensitive organs were defined in the hybrid model. The developed model was implemented into a Monte Carlo particle transport simulation code, MCNPX, and used to calculate the organ doses, which were then compared with the TLD measured values.
키워드
voxel model; hybrid; ATOM phantom; MIRD5 mathematical phantom; Monte Carlo; organ dose calculations; RANDO PHANTOM; ANTHROPOMORPHIC PHANTOMS; CT
- 제목
- ATOM-MIRD Hybrid Voxel Model for Monte Carlo Calculations of Organ Doses: A Complement to a Physical Phantom
- 저자
- Cho, Sungkoo; Choi, Sang Hyoun; Yi, Chul-Young; Kim, Chan Hyeong
- 발행일
- 2008-06
- 유형
- Article; Proceedings Paper
- 페이지
- 306 ~ 308