Laparoendoscopic Single-site Repair of Bladder Rupture Using a Home-made Single-port Device: Initial Experience of Treatment for a Traumatic Intraperitoneal Bladder Rupture

Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

We report our initial experience with a laparoendoscopic single-site (LESS) repair of a bladder rupture using a home-made single-port device. A 37-year-old man presented to the emergency department with complaints of voiding difficulty and gross hematuria after blunt trauma. Cystography and computed tomography revealed an intraperitoneal bladder rupture. The patient underwent LESS repair of a bladder rupture using the Alexis wound retractor, which was inserted through the umbilical incision. A home-made single-port device was made by fixing 6 1/2 surgical gloves to the outer rim of the retractor and securing the glove finger to the end of 3 trocars with a tie. Using the flexible laparoscopic instruments and rigid instruments, LESS surgery was performed using a procedure similar to conventional laparoscopic surgery. The patient did not have any voiding problem after removal of the urethral Foley catheter on the 10th postoperative day. To our knowledge, this is the first published report of LESS repair of a traumatic bladder rupture using a home-made single-port device in the literature.

키워드

laparoscopyinstrumentationurinary bladderruptureLAPAROSCOPIC SURGERYMANAGEMENTUROLOGY
제목
Laparoendoscopic Single-site Repair of Bladder Rupture Using a Home-made Single-port Device: Initial Experience of Treatment for a Traumatic Intraperitoneal Bladder Rupture
저자
Lee, Joo YongKang, Dong HyukLee, Seung Wook
DOI
10.1097/SLE.0b013e318248ad68
발행일
2012-06
유형
Article
저널명
Surgical Laparoscopy, Endoscopy and Percutaneous Techniques
22
3
페이지
eE135 ~ eE137