화재 시 하중 재하 조건에 따른 중공슬래브의 내화거동 및 잔존성능

Fire Resistance Behavior and Residual Capacity of Voided Slab Subjected to Fire According to Loading Condition

초록

This study presents experimental investigation on the residual capacity of fire-damaged voided slabs according to loading conditions. In this study, two voided slab specimens were fabricated, and heated by ISO standard fire during 120 minutes with different loading conditions of presence of loading. These specimens were cooled down to room temperature, and the residual capacity of fire-damaged voided slabs was investigated. Based on test results, thermal distribution of voided slab through the depth of concrete sections is different by the loading conditions. The temperature of loaded specimen is rapidly elevated through the whole depth of concrete sections compared to the unloaded specimen. The residual strength of fire-damaged voided slab specimens are 60% and 66% of that of voided slab specimen without fire damage, and the residual stiffness of fire-damaged voided slab specimens decreases by 15%~23% of that of voided slab specimen without fire damage. In case of voided slab specimens subjected ISO standard fire, the loaded specimen shows the decrease of 10% in the residual strength and the decrease of 15% in the residual stiffness compared to the unloaded specimen. It seems to result from higher temperature of bottom reinforcements in the loaded specimen due to the cracks, and more extensive damage on concrete cover of reinforcements by spalling process according to load level.

키워드

Voided slabResidual capacityThermal distributionLoading condition중공슬래브잔류성능온도분포하중조건
제목
화재 시 하중 재하 조건에 따른 중공슬래브의 내화거동 및 잔존성능
제목 (타언어)
Fire Resistance Behavior and Residual Capacity of Voided Slab Subjected to Fire According to Loading Condition
저자
최현기배백일정형석최창식정주홍
DOI
10.11112/jksmi.2018.22.1.099
발행일
2018-01
저널명
한국구조물진단유지관리공학회 논문집
22
1
페이지
99 ~ 106

파일 다운로드