Nonlinear finite element analysis of shearwalls with various types of openings

Citations

SCOPUS

0

초록

The installation of new opening is necessary for remodeling project, house merging type. Current structural design code cannot provide the deterministic way for designing the shear walls with openings. So many engineers prefer to retrofit the perforated wall area for the structural safety. For the safe design of retroftitting, for the perforated structural walls, we carried out nonlinear finite element analysis to find the coupling effect of remaing walls. Specifically, many types of shapes were considered and various area of rectangular openings were analyzed. For the effective retrofitting, door shape and such area about 20% of wall is appropriate for retrofitting of reinforced concrete shearwalls.

키워드

Coupling elementsFEMOpening shapeShearwallCoupling effectCoupling elementFEMNon-linear finite-element analysisOpening shapePerforated wallsSafe designsStructural design codesStructural safetyStructural wallsReinforced concreteRetrofittingShear flowShear wallsStructural designFinite element method
제목
Nonlinear finite element analysis of shearwalls with various types of openings
저자
Bae, Baek-ilChoi, Hyun KiChoi, Chang Sik
DOI
10.4028/www.scientific.net/AMR.194-196.1900
발행일
2011-02
유형
Conference Paper
저널명
Advanced Materials Research
194-196
페이지
1900 ~ 1903