PARaDIM: A PHITS-Based Monte Carlo Tool for Internal Dosimetry with Tetrahedral Mesh Computational Phantoms

  • Carter, Lukas M.
  • Crawford, Troy M.
  • Sato, Tatsuhiko
  • Furuta, Takuya
  • Choi, Chansoo
  • ... Kim, Chan Hyeong
  • 외 4명
Citations

WEB OF SCIENCE

32
Citations

SCOPUS

36

초록

Mesh-type and voxel-based computational phantoms comprise the current state of the art for internal dose assessment via Monte Carlo simulations but excel in different aspects, with mesh-type phantoms offering advantages over their voxel counterparts in terms of their flexibility and realistic representation of detailed patient- or subject-specific anatomy. We have developed PARaDIM (pronounced "paradigm": Particle and Heavy Ion Transport Code System-Based Application for Radionuclide Dosimetry in Meshes), a freeware application for implementing tetrahedral mesh-type phantoms in absorbed dose calculations. It considers all medically relevant radionuclides, including alpha, beta, gamma, positron, and Auger/conversion electron emitters, and handles calculation of mean dose to individual regions, as well as 3-dimensional dose distributions for visualization and analysis in a variety of medical imaging software. This work describes the development of PARaDIM, documents the measures taken to test and validate its performance, and presents examples of its uses. Methods: Human, small-animal, and cell-level dose calculations were performed with PARaDIM and the results compared with those of widely accepted dosimetry programs and literature data. Several tetrahedral phantoms were developed or adapted using computer-aided modeling techniques for these comparisons. Results: For human dose calculations, agreement of PARaDIM with OLINDA 2.0 was good-within 10%-20% for most organs-despite geometric differences among the phantoms tested. Agreement with MIRDcell for cell-level S value calculations was within 5% in most cases. Conclusion: PARaDIM extends the use of Monte Carlo dose calculations to the broader community in nuclear medicine by providing a user-friendly graphical user interface for calculation setup and execution. PARaDIM lever-ages the enhanced anatomic realism provided by advanced computational reference phantoms or bespoke image-derived phantoms to enable improved assessments of radiation doses in a variety of radiopharmaceutical use cases, research, and preclinical development.

키워드

PARaDIMPHITSdosimetrytetrahedral meshphantomMONOENERGETIC ELECTRONS-VALUESPARTICLERADIATIONSOFTWAREVERSION
제목
PARaDIM: A PHITS-Based Monte Carlo Tool for Internal Dosimetry with Tetrahedral Mesh Computational Phantoms
저자
Carter, Lukas M.Crawford, Troy M.Sato, TatsuhikoFuruta, TakuyaChoi, ChansooKim, Chan HyeongBrown, Justin L.Bolch, Wesley E.Zanzonico, Pat B.Lewis, Jason S.
DOI
10.2967/jnumed.119.229013
발행일
2019-12
유형
Article
저널명
Journal of Nuclear Medicine
60
12
페이지
1802 ~ 1811

파일 다운로드