접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향

Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers
  • 최익황
  • 이재익
  • 권구도
  • 장경영

초록

Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Thus, in this study, we investigate the effects of such experimental system dependent factors in the measurement of ultrasonic nonlinear parameter by using contact PZT transducer. Experimental results showed that the effect of system dependent nonlinearity is reduced when the contact pressure and transducer input voltage are sufficiently large. These results will be very useful to find out the proper experiment condition to measure rather accurate nonlinear parameter.

키워드

Ultrasonic Nonlinear ParameterContacting PressureContact Type TransducerSystem Dependent HarmonicMaterial Dependent Harmonic초음파 비선형파라미터접촉압력접촉식 탐촉자시스템 비선형성재료의 비선형성
제목
접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향
제목 (타언어)
Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers
저자
최익황이재익권구도장경영
발행일
2008-08
저널명
비파괴검사학회지
28
4
페이지
358 ~ 363