Comparative analysis of single-cascade five-zone and two-zone SMB systems for the separation of a ternary amino acid mixture

  • Jo, Se Hee
  • Kim, Jeung Kun
  • Yool, Chang Geun
  • Kim, Jin Il
  • Koo, Yoon Mo
  • ... Mun, Sunyong
Citations

WEB OF SCIENCE

9
Citations

SCOPUS

10

초록

A ternary separation usually requires the use of two simulated moving bed (SMB) units in series. Since an increase in the number of SMB units leads to a significant increase in capital and operational costs, the use of a single SMB unit is preferred if its structure can be modified to treat a ternary separation. Such a modified single SMB unit has been typified by a five-zone SMB or a two-zone SMB so far. The separation performances of a five-zone SMB and a two-zone SMB are compared in this paper by using the ternary amino acid mixture as a model system. A five-zone SMB is designed with the safety margin method while a two-zone SMB is optimized using genetic algorithm. A five-zone SMB based on the maximum allowable safety margin, although it may not guarantee the global optimum solution, results in much better separation performance than a two-zone SMB at its global optimum state.

키워드

five-zone SMBtwo-zone SMBternary separationsafety margin methodCOUNTERCURRENT ADSORPTION SYSTEMMOVING-BED CHROMATOGRAPHYMULTIOBJECTIVE OPTIMIZATIONFLOW-RATESDESIGNIDEALMODEL
제목
Comparative analysis of single-cascade five-zone and two-zone SMB systems for the separation of a ternary amino acid mixture
저자
Jo, Se HeeKim, Jeung KunYool, Chang GeunKim, Jin IlKoo, Yoon MoMun, Sunyong
DOI
10.1002/cjce.5450850608
발행일
2007-12
유형
Article
저널명
Canadian Journal of Chemical Engineering
85
6
페이지
874 ~ 882