560 MW 석탄화력발전소 해수온도 상승에 따른 복수기 압력 손실 최소화 방안

A Study on Minimizing of Condenser Pressure Loss according to the Temperature Rise of the Seawater for 560 MW Coal-fired Power Plants

초록

In this paper, studied condenser operating management which is affecting power plants efficiency considering the cost of poor quality. Sea water temperature and condenser pressure have clear correlation in S power plants. As the sea water temperature changes, condenser pressure changed -1.7 ~ +20 mmHg from design condenser pressure(38.1 mmHg). Use the heat rate correction curve from manufactory company, realized that efficiency and cost of poor quality changed 0.0201%, 12,830 won/h at Unit #1,2 but 0.0155%, 9,832 won/h when condenser pressure 1 mmHg rise. Also, checked that it is changed depend on seasonal corresponding operation, plant ageing and the point of preventive maintenance like overhaul maintenance. This study said if we considered complying with management range and planning overhaul maintenance, then it could help reducing operating maintenance losses minimum 2.5 billion won per 1 year (case : Unit #1, forty days maintenance).

키워드

condenser pressure (복수기 압력)cost of poor quality (손실비용)heat rate (열소비율)control chart(관리도)
제목
560 MW 석탄화력발전소 해수온도 상승에 따른 복수기 압력 손실 최소화 방안
제목 (타언어)
A Study on Minimizing of Condenser Pressure Loss according to the Temperature Rise of the Seawater for 560 MW Coal-fired Power Plants
저자
안효열문승재
발행일
2014-07
유형
Proceeding
저널명
2014 한국플랜트학회 학술대회
2014
1
페이지
159 ~ 164