하이브리드 프리캐스트 보-기둥 접합부의 해석적 연구

Analytical Study on Hybrid Precast Concrete Beam-Column Connections

초록

Non-linear finite element analysis for newly developed precast concrete details for beam-to-column connection which can be used in moderate seismic region was carried out in this study. Developed precast system is based on composite structure and which have steel tube in column and steel plate in beam. Improving cracking strength of joint under reversed cyclic loading, joint area was casted with ECC(Engineering Cementitious Composites). Since this newly developed precast system have complex sectional properties and newly developed material, new analysis method should be developed. Using embedded elements and models of non-linear finite element analysis program ABAQUS previously tested specimens were successfully analyzed. Analysis results show comparatively accurate and conservative prediction. Using finite element model, effect of axial load magnitude and flexural strength ratio were investigated. Developed connection have optimized performance under axial load of 10~20% of compressive strength of column. Plastic hinge was successfully developed with flexural strength ratio greater than 1.2.

키워드

beam-to-column jointhybrid connectionnon-linear finite element analysisaxial loadflexural strength ratio보-기둥 접합부하이브리드 연결부비선형 유한요소해석압축력휨강도비
제목
하이브리드 프리캐스트 보-기둥 접합부의 해석적 연구
제목 (타언어)
Analytical Study on Hybrid Precast Concrete Beam-Column Connections
저자
최창식김승현최윤철최현기
DOI
10.4334/JKCI.2013.25.6.631
발행일
2013-12
저널명
콘크리트학회 논문집
25
6
페이지
631 ~ 639

파일 다운로드