Body-size-dependent phantom library constructed from ICRP mesh-type reference computational phantoms

  • Choi, Chansoo
  • Yeom, Yeon Soo
  • Lee, Hanjin
  • Han, Haegin
  • Shin, Bangho
  • ... Kim, Chan Hyeong
  • 외 1명
Citations

WEB OF SCIENCE

35
Citations

SCOPUS

39

초록

Recently, ICRP Task Group 103 developed new mesh-type reference computational phantoms (MRCPs) for the adult male and female by converting the current voxel-type reference computational phantoms (VRCPs) of ICRPPublication 110into a high-quality/fidelity mesh format. Utilizing the great deformability/flexibility of the MRCPs compared with the VRCPs, in the present study, we established a body-size-dependent phantom library by modifying the MRCPs. The established library includes 108 adult male and 104 adult female phantoms in different standing heights and body weights, covering most body sizes representative of Caucasian and Asian populations. Ten secondary anthropometric parameters with respect to standing height and body weight were derived from various anthropometric databases and applied in the construction of the phantom library. An in-house program for automatic phantom adjustment was developed and applied for practical construction of such a large number of phantoms in the library with minimized human intervention. Organ/tissue doses calculated with three male phantoms in different standing heights (165, 175, and 190 cm) with a fixed body weight of 80 kg for external exposures to broad parallel photon beams from 0.01 to 10(4)MeV were compared, observing there are significant dose differences particularly for the photon energies <0.1 MeV in which the organ/tissue doses tended to increase with increasing standing height. In addition, the organ/tissue doses of three female phantoms in different body weights (45, 65, and 140 kg) with a fixed standing height of 165 cm were compared, showing a significant decreasing tendency with increasing body weight for the photon energies <10 MeV. For the higher energies, the opposite trend, interestingly, was observed; that is, the organ/tissue doses tended to increase with increasing body weight. The results, despite the limited number of exposure cases, suggest that the use of the body-size-dependent phantom library can improve the accuracy of individual dose estimates for many retrospective dosimetry studies by taking the body size of individuals into account.

키워드

ICRP reference phantomnon-reference phantommesh phantomphantom librarybody sizeMonte Carlo simulationindividual dose reconstructionADULT HUMAN PHANTOMSMASS INDEXFEMALEDISTRIBUTIONSPOPULATIONTRANSPORTMODELS
제목
Body-size-dependent phantom library constructed from ICRP mesh-type reference computational phantoms
저자
Choi, ChansooYeom, Yeon SooLee, HanjinHan, HaeginShin, BanghoThang Tat NguyenKim, Chan Hyeong
DOI
10.1088/1361-6560/ab8ddc
발행일
2020-06
유형
Article
저널명
Physics in Medicine and Biology
65
12
페이지
1 ~ 15