초록
A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Prot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.
키워드
- 제목
- 압전형 수신 기법을 이용한 초음파 절대변위진폭 측정
- 제목 (타언어)
- Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method
- 저자
- Park, Seong-Hyun; Kim, Jongbeom; Jhang, Kyung-Young
- 발행일
- 2017-02
- 유형
- Article
- 저널명
- 비파괴검사학회지
- 권
- 37
- 호
- 1
- 페이지
- 7 ~ 12