천연가스 화력발전소의 탈질설비 입구 질소산화물 농도와 영향인자와의 상관관계 분석

Correlation Analysis of NOx Concentration at the Inlet of De-NOx System and Influence Factors in a Natural Gas Fired Thermal Power Plant

초록

Natural Gas Fired Thermal Power Plant to target concentration of 150 ppm NOx emission by the output exceeds 110 MW research interval range. Nitrogen Oxides concentration correlation equation is made by correlation and regression analysis for replace when analyzer has trouble. Calculated and measured value compared and the following conclusions were obtained. In the rated power of the flue gas Nitrogen Oxides concentration calculated by the equation calculated value and the error of the measured value of 1% or less and it is more less than analyzer accuracy of inspection legal standard error 20% Nitrogen Oxides concentration calculated value of rated output is possible to alternative was confirmed.

키워드

Nitrogen Oxide (질소산화물)Nitrogen Oxide Analyzer (질소산화물농도 분석장치)Flue Gas (배기가스)Correlation Analysis (상관관계분석)Regression Analysis(회귀분석)
제목
천연가스 화력발전소의 탈질설비 입구 질소산화물 농도와 영향인자와의 상관관계 분석
제목 (타언어)
Correlation Analysis of NOx Concentration at the Inlet of De-NOx System and Influence Factors in a Natural Gas Fired Thermal Power Plant
저자
박주경유호선문승재
발행일
2014-07
유형
Proceeding
저널명
2014 한국플랜트학회 학술대회
2014
1
페이지
67 ~ 73