전열교환 환기장치의 동절기 결로 방지를 위한 지역별 예열코일 용량 산정 및 분석

Computation and Analysis of Preheat coil Capacity to Prevent Frosting in Winter Season in Korea
  • 김원준
  • 김희정
  • 윤동섭
  • 정재원

초록

A heat and energy exchanger saves ventilation energy in buildings by recovering the sensible and latent heat from the return air. The condensation caused from temperature difference when energy exchange occurs between indoor air and outdoor air gets frozen once it meets outdoor air colder than the freezing point. Many studies were conducted to solve this problem. However in this study, we prevent frozing problem to installing a preheating coil at supply-outdoor sides of energy exchanger. And calculate the temperature of frosting threshold and it’s capcity mathematically. Also this process applied to outdoor condition of local area for suggest local area’s preheating capacity.

키워드

전열교환기현열교환기결빙현상예열기예열코일Enthalpy ExchangerHeat exchangerFrost problemPreheaterPreheat coil
제목
전열교환 환기장치의 동절기 결로 방지를 위한 지역별 예열코일 용량 산정 및 분석
제목 (타언어)
Computation and Analysis of Preheat coil Capacity to Prevent Frosting in Winter Season in Korea
저자
김원준김희정윤동섭정재원
발행일
2016-04
유형
Proceeding
저널명
대한건축학회 2016년도 춘계학술발표대회논문집
36
1
페이지
263 ~ 264