Determination of beam quality correction factors for alanine dosimetry in clinical proton beams

  • Kim, Chae-Eon
  • Park, Jong In
  • Jung, Seongmoon
  • Pak, Sang-il
  • Jeong, Seonghoon
  • ... Chung, Yoonsun
  • 외 8명
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

Introduction: With the advent of FLASH radiotherapy, alanine dosimetry has gained attention as a promising dosimeter owing to its dose-rate independence. However, before utilized in radiotherapy, procedures for determining the absorbed dose to water using alanine under clinical proton beams must be established. This study sought to develop a formula for alanine dosimetry by deriving beam quality correction factors and validating them through Monte Carlo simulations and experimental measurements. Materials and Methods: To calculate the absorbed dose to water using alanine dosimeters, a formula was developed specifically for the plateau region. Alanine dosimeters were irradiated under both a reference beam (Cobalt-60) and clinical proton beams. Beam quality correction factors were calculated and subsequently validated through Monte Carlo simulations using the Tool for Particle Simulation (TOPAS), which is based on GEANT4, as well as through experimental measurements. During the simulations, both crystalline and bulk densities of alanine were considered. Results: The simulation results showed that the average beam quality correction factors for alanine were 1.005 for crystalline density and 1.012 for bulk density. Experimental measurements under clinical proton beams yielded a beam quality correction factor of 1.014, with a standard uncertainty of 2.2%. Conclusions: These results suggest that alanine dosimeters provide reliable and reproducible measurements for proton therapy. The robust methodology demonstrated here highlights the potential of alanine dosimeters in clinical applications, demonstrating their effectiveness and reliability in determining the absorbed dose to water under clinical proton beam conditions.

키워드

Alanine dosimetryBeam quality correction factorProton therapyTOPAS/GEANT4HIGH-ENERGY PHOTONX-RAYRELATIVE RESPONSEDEPENDENCEVALIDATIONTG-51
제목
Determination of beam quality correction factors for alanine dosimetry in clinical proton beams
저자
Kim, Chae-EonPark, Jong InJung, SeongmoonPak, Sang-ilJeong, SeonghoonAn, SeohyeonKim, ChankyuJeong, Jong HwiKim, HaksooLim, Young KyungShin, DonghoChung, YoonsunKim, In JungLee, Se Byeong
DOI
10.1016/j.ejmp.2025.104992
발행일
2025-06
유형
Article
저널명
Physica Medica
134
페이지
1 ~ 9