상세 보기
Development of 2-phase/4-phase flat-type vibration motor
- Won, Sung Hong;
- Lim, Seung-Bin;
- Koo, Dae Hyun;
- Lee, Ju
Citations
WEB OF SCIENCE
1Citations
SCOPUS
2초록
Due to the mechanical angle error between two brushes and commutation patterns on the rotor PCB, a fatal defect-starting failure-could be detected in the vibration motor. In order to eliminate this failure, we have developed a new winding method, double winding, to make a 4-phase vibration motor with only 2 bunches of coil. By this winding method, we could eliminate the starting failure successfully and save the manufacturing cost.
키워드
starting failure; 2/4 phase; vibration motor; MOBILE PHONE
- 제목
- Development of 2-phase/4-phase flat-type vibration motor
- 저자
- Won, Sung Hong; Lim, Seung-Bin; Koo, Dae Hyun; Lee, Ju
- 발행일
- 2006-10
- 유형
- Article; Proceedings Paper
- 권
- 42
- 호
- 10
- 페이지
- 3482 ~ 3484