Transfer length in full-scale pretensioned concrete beams with 1.4 m and 2.4 m section depths

  • Yang, Jun-Mo
  • Kim, Jin-Kook
  • Yoo, Doo-Yeol
Citations

WEB OF SCIENCE

9
Citations

SCOPUS

10

초록

This study aims to investigate the transfer length of full-scale prestressed concrete (PSC) beams with lengths of 30 in and 35 m and section depths of 1.4 m and 2.4 m for highway and railway bridge girders, respectively. To do this, newly developed high-strength (f(pu) of 2400 MPa) prestressing (PS) strands were used. The initial and effective prestressing forces applied were 94% of the yield strength and 70% of the ultimate tensile strength of the strands. The difference between the transfer lengths at the cut end and dead end was reduced by increasing the section depth. Greater strains were found at the cut end due to a lateral expansion of the strands by the Royer effect compared with those at the dead end, causing a greater stress concentration. The eight most widely used prediction models were adopted to predict the transfer lengths of high-strength PS strands in full-scale PSC beams, and it was found that all models significantly overestimated the transfer lengths. Accordingly, the conservative use of the ACI recommendation of 50d(b) is suggested based on this study.

키워드

Full-scale PSC beamHigh-strength strandTransfer lengthSection depthRoyer effectPRESTRESSING STRANDBEHAVIORMEMBERSPREDICTIONBONDMPA
제목
Transfer length in full-scale pretensioned concrete beams with 1.4 m and 2.4 m section depths
저자
Yang, Jun-MoKim, Jin-KookYoo, Doo-Yeol
DOI
10.1016/j.engstruct.2018.05.104
발행일
2018-09
유형
Article
저널명
Engineering Structures
171
페이지
433 ~ 444