상세 보기
The fabrication and characterization of the real-time dust monitoring cantilever sensor
초록
We fabricated the cantilever sensor for highly sensitive dust monitoring by using electrostatic force. The cantilever`s dimension was 700 ?m × 100 ?m × 8.6 ?m and a 1 mm × 1 mm × 8.6 ?m paddle was added to the end of the cantilever for improvement of sensitivity. When the applying voltage was increasing, the saturation of the phase change increased from 0.4 ˚at 30 %RH to 0.6 ˚at 50 %RH for the small-sized dust particles, and the bigger-sized dust particles were hardly attached and detached at 50 %RH. The phase change was increased by 0.2 ˚/min, 20 % of the dust particles were still attached though the twice higher negative voltage was applied at 50 %RH.
- 제목
- The fabrication and characterization of the real-time dust monitoring cantilever sensor
- 저자
- 이승백
- 발행일
- 2008-09-17
- 학회명
- The 34th International Conference on Micro & Nano Engineering
- 개최지
- Athens, Greece