강섬유 혼입률에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능

Seismic Performance of Reinforced Concrete Exterior Beam-Column Joint according to Steel Fiber Volume Fraction

초록

The purpose of this study is to evaluate the seismic performance of steel fiber reinforced concrete by setting the steel fiber volume fraction to 0, 1, 2%. Experimental results were evaluated according to the criteria presented in ACI 374. All specimens except the NJR-2 specimens did not meet the criteria. However, NJR-1 satisfied the criterion that the secant stiffness between -0.0035 and 0.0035 of the members should exceed 0.05 of the initial stiffness of the first cycle.

제목
강섬유 혼입률에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능
제목 (타언어)
Seismic Performance of Reinforced Concrete Exterior Beam-Column Joint according to Steel Fiber Volume Fraction
저자
이장재 최창식
발행일
2017-11
유형
Proceeding
저널명
한국콘크리트학회 2017 가을 학술대회 논문집
29
2
페이지
175 ~ 176