Performance of 500 MW thermal power plants depending on driving methods of boiler feedwater pumps

Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Two driving methods are primarily used for boiler feedwater pumps (BFPs): turbine and motor. Turbine-driven BFPs (BFPTs) are typically implemented in large-capacity coal-fired power plants in Korea owing to their greater efficiency than motor-driven BFPs (BFPMs). In this study, we analyzed the performance of BFP-driven power plants and proposed a more efficient driving method based on BFPs. For the reference power plant, the BFPM was implemented to improve its performance since the efficiency of BFPM was 14.83 % higher than that of BFPT. A 1 % increase in the efficiency of the BFPT and BFPM presents a net output increase of 251.3 and 235.0 kW respectively. This additional power output reduces the effect of greenhouse gas emissions. The condenser pressure is also a key parameter for determining the BFP driver.

키워드

Thermal power plantBoiler feedwater pumpGreenhouse gas emissionTHERMODYNAMIC ANALYSISSOLARGENERATIONOPTIMIZATIONIMPROVEMENTSYSTEM
제목
Performance of 500 MW thermal power plants depending on driving methods of boiler feedwater pumps
저자
Jang, Yong ChuPark, Kyung HoonMoon, Seung Jae
DOI
10.1007/s12206-025-0643-1
발행일
2025-07
유형
Article
저널명
Journal of Mechanical Science and Technology
39
7
페이지
4227 ~ 4237