The paper discusses the influence of a grid impedance, especially for a leakage inductance of a grid side transformer. The grid impedance does not usually take into account during the design stage of the current controller. As a result, low order harmonics in the grid current are distorted. In this paper, the active feed-forward compensation method is proposed for the purpose of attenuating the current distortion. The proposed method can be applied to L filter as well as LCL filter. The effectiveness of the method is verified through various simulations and experiments based on a 1.5kW voltage source inverter prototype.

키워드

Active feedforwardharmonic compensationlow frequency transformerlow order harmonicTHDweak gridFeed-ForwardHarmonic compensationlow frequency transformerLow order harmonicsTHDWeak gridElectric invertersIndustrial electronicsPower convertersHarmonic analysis
제목
An active feedforward compensation for a current harmonics reduction in three-phase grid-connected inverters
저자
Park, Byong-JunChoi, Ki-YoungKim, Rae-Young
DOI
10.1109/IECON.2013.6699169
발행일
2014-01
유형
Conference Paper
저널명
Proceedings of the Annual Conference of the IEEE Industrial Electronics Society (IECON)
페이지
400 ~ 405