상세 보기
고강도강 기둥을 적용한 WUF-W 접합부의 반복하중 실험
- 문기훈;
- 김종민;
- 한상환
초록
The purpose of this study is to evaluate the seismic performance of Welded Unreinforced Flange-Welded Web connections with the column composed of high-performance steel. The study involved the inelastic cyclic testing of 4 full-scale connection specimens to evaluate the effect of column strength and beam depth. The specimens were designed to strong column-weak beam and balanced panel zone. 3 of 4 specimens including 2 specimens consisted of high-performance steel column are achieved total story drift of 0.04 rad or more prior to failure. The test results showed that ductility capacity of connections with high-performance steel column is sufficient in light of current AISC seismic design. Energy dissipation in specimens consisting of high-performance steel column is less than those of normal strength steel column.
- 제목
- 고강도강 기둥을 적용한 WUF-W 접합부의 반복하중 실험
- 제목 (타언어)
- Cyclic Loading Experiment of Welded Unreinforced Flange Welded Web(WUF-W) Connections with High-Performance Steel Column
- 저자
- 문기훈; 김종민; 한상환
- 발행일
- 2011-03
- 유형
- Proceeding
- 저널명
- 한국지진공학회 2011년도 학술발표회 논문집
- 페이지
- 141 ~ 144