탱크 컨테이너에서 불화수소 누출 시 인근지역 피해범위 분석

Off-site Consequence Analysis for Hydrogen Fluoride Release from a Tank Container

초록

This study was to choose a leakage model by using the hydrogen fluoride and the physical-chemical data in the tank container which stored the hydrogen fluoride. And, this study was to predict each extend of damage while it changed the meteorological data like temperature and wind speed, etc. Based on the forecast result, this study was to create the worst-case scenario against the leakage of hydrogen fluoride from the tank container. To conclude, it needs to take a measure in order to make the workers and residents 2.21 km away evacuate within one hour when the hydrogen fluoride leaks from the tank container in case of 37 G air temperature, 1.5 m/s wind speed, F-class atmospheric stability, and urban area as terrestrial condition.

키워드

hydrogen fluoride(⿞불화수소)tank container(탱크 컨테이너)worst-case scenario(최악의 누출 시나리오)
제목
탱크 컨테이너에서 불화수소 누출 시 인근지역 피해범위 분석
제목 (타언어)
Off-site Consequence Analysis for Hydrogen Fluoride Release from a Tank Container
저자
우종운문승재
발행일
2014-07
유형
Proceeding
저널명
2014 한국플랜트학회 학술대회
2014
1
페이지
81 ~ 85