초록
The frost and freezing on contact wire in winter is a very serious problem Shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire. Extra electrical resistance, which may affect Quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing system is to melt frost or freezing in contact wire. 111e principle of de-icing system is to melt frost or ice by Joule heat of contact wire impedance. The temperature of the contact wire was increased with increasing the current. But temperature of contact wire was decreased with increasing the velocity of th wind.
키워드
De-Icing System; Overhead Contact Wire; Railway; Configuration Process
- 제목
- 해빙시스템에 의한 전차선의 온도변화에 관한 연구
- 제목 (타언어)
- A Study on Temperature Variation of Contact Wire by De-icing System
- 저자
- 안병립; 이주
- 발행일
- 2008-09
- 저널명
- 조명.전기설비학회논문지
- 권
- 22
- 호
- 9
- 페이지
- 69 ~ 74