상세 보기
초록
An auditory experiment was conducted to establish annoyance criteria for floor impact noise in apartment buildings. Heavyweight floor impact sounds were recorded using an impact ball; the im-pact sound pressure level (SPL) together with the temporal decay rate (DR), which is quantified by the dB drop per second, was analyzed. For the experiment, A-weighted exposure levels of the heavy-weight floor impact sounds ranging 34~73 dB were evaluated at 3 dB intervals. Participants used a 7-point verbal scale to evaluate the level of annoyance from floor impact noise. The results show that the annoyance increases with increasing impact SPL and decreasing DR. Consequently, a classi-fication and an acceptable level of floor impact sounds were proposed.
키워드
- 제목
- 감성평가 기반 바닥충격음 등급화 및 수인한도 설정
- 제목 (타언어)
- Floor impact sound classification and setting Acceptable limit based on psychoacoustical evaluation
- 저자
- 김성민; 홍주영; 전진용
- 발행일
- 2014-10
- 유형
- Proceeding
- 저널명
- 한국소음진동공학회 2014년 추계학술대회논문집
- 페이지
- 7 ~ 9