공동주택의 냉난방 및 급탕 겸용 히트펌프의 에너지 성능 분석

Energy performance of Heat Pump for Cooling, Heating and Hot Water Supply in an Apartment Building
  • 황유진
  • 강용권
  • 조혜진
  • 조수영
  • 정재원

초록

Recently, the importance of reducing energy in buildings is more and more growing and feasible by applying an efficient machinery to handle building loads. This study analyzes the potential of arrangement of heat pumps in design and compares the energy performance of a boiler and several heat pump systems arranged by handling loads as the integrated cooling, heating and hot water supply systems. The specifications and details of the systems in energy simulation was referred to EnergyPlus model and performed through EES program. The result shows that a single heat pump combined with sufficient heat source system (case 1) consumed 50.3% less primary energy compared to the reference system. Double heat pump handling heating and hot water loads separately (case 2) requires 24.6% less primary energy than a reference boiler system. The energy consumption of cascade heat pump system (case 3) is 46.5% less than a reference system and 7% more than a single heat pump system.

키워드

Heat pumpAll-in-one systemCoolingheating and hot water supply system히트펌프통합 시스템냉난방 급탕 시스템