상세 보기
DEVELOPMENT OF FEMALE ATOM-MIRD HYBRID VOXEL MODEL FOR MONTE CARLO DOSE CALCULATIONS
- Cho, Sungkoo;
- Yang, Il Hyuk;
- Jeong, Jong Hwi;
- Kim, Chan Hyeong
Citations
WEB OF SCIENCE
0Citations
SCOPUS
1초록
A hybrid-type female computational model was constructed by combining the tomographic voxel model of the A TOM adult female physical phantom with the mathematical organ models of the MIRD5 stylized phantom. The constructed model has 13 internal organs: 5 organs from the ATOM phantom and the other 8 organs from the MIRD5 phantom. The model was employed in Monte Carlo dose calculations with MCNPX to calculate organ doses, and the calculated values were compared with the values of Regina for reference external irradiation conditions.
키워드
hybrid voxel model; female ATOM phantom; Monte Carlo; ANTHROPOMORPHIC PHANTOMS; CT
- 제목
- DEVELOPMENT OF FEMALE ATOM-MIRD HYBRID VOXEL MODEL FOR MONTE CARLO DOSE CALCULATIONS
- 저자
- Cho, Sungkoo; Yang, Il Hyuk; Jeong, Jong Hwi; Kim, Chan Hyeong
- 발행일
- 2009-10
- 유형
- Article; Proceedings Paper
- 권
- 168
- 호
- 1
- 페이지
- 209 ~ 212