Effectiveness and adverse effects of in-vessel retention strategies under a postulated SGTR accident of an OPR1000

Citations

WEB OF SCIENCE

10
Citations

SCOPUS

11

초록

During a steam generator tube rupture (SGTR) accident, direct release of radioactive nuclides into the environment is postulated via bypassing the containment building. This conveys a significant threat in severe accident management (SAM) for minimization of radionuclide release. To mitigate this risk, a numerical assessment of SAM strategies was performed for an SGTR accident of an Optimized Power Reactor 1000 MWe (OPR1000) using MELCOR code. Three in-vessel mitigation strategies were evaluated and the effect of delayed operation action was analyzed. The MELCOR calculations showed that activation of a prompt secondary feed and bleed (F&B) operation using auxiliary feed water and use of an atmospheric dump valve could prevent core degradation. However, depressurization using the safety depressurization system could not prevent core degradation, and the injection of coolant via high-pressure safety injection without the use of reactor coolant system (RCS) depressurization increased fission product release. When mitigation action was delayed by 30 minutes after SAMG entrance, a secondary F&B operation failed in depressurizing the RCS sufficiently, and a significant amount of fission products were released into the environment. These results suggest that appropriate mitigation actions should be applied in a timely manner to achieve the optimal mitigation effects.

키워드

Severe accident managementOPR1000MELCOReffectiveness and adverse effectsSGTRin-vessel mitigationfission product retentionRCS DEPRESSURIZATION STRATEGYSTEAM-GENERATORSCENARIOS
제목
Effectiveness and adverse effects of in-vessel retention strategies under a postulated SGTR accident of an OPR1000
저자
Choia, WonjunKim, Hwan-YeolPark, Rae-JoonKim, Sung Joong
DOI
10.1080/00223131.2016.1273145
발행일
2017-01
유형
Article
저널명
Journal of Nuclear Science and Technology
54
3
페이지
337 ~ 347