상세 보기
RC 보-기둥 접합부의 2방향 내진거동 평가
Seismic Behavior of RC Beam-column Connections Under Uni- and Bidirectional Loads
- 한지민;
- 한상환
초록
In this study, the hysteretic behavior of RC beam-column joints was evaluated throughout experimental tests. Two full-scale specimens were constructed according to current standards design provisions, and tested under reversed cyclic loads. One specimen was subjected to unidirectional loading and the other was subjected to bidirectional loading. Experimental results show that the hysteresis behavior of the joint was greatly affected by loading types.
- 제목
- RC 보-기둥 접합부의 2방향 내진거동 평가
- 제목 (타언어)
- Seismic Behavior of RC Beam-column Connections Under Uni- and Bidirectional Loads
- 저자
- 한지민; 한상환
- 발행일
- 2019-05
- 유형
- Proceeding
- 저널명
- 한국콘크리트학회 2019년도 봄 학술대회 논문집
- 권
- 31
- 호
- 1
- 페이지
- 213 ~ 214