초록
The central purpose of this research was to propose spray tower dehumidification effectiveness correlations useful for liquiddesiccant integrated system design and analysis. In this research, Liquid desiccant air conditioning system performance datagenerated using established literature reviews were statistically analyzed by design expert. The normal common desiccantsolutions; TEG and common types of tower; spray tower, were analyzed. Proposed correlations relates the spray towerdehumidification effectiveness as a function of five parameters; L/G(Liquid to gas ratio), inlet air and solution temperature, inletair relative humidity, solution concentration.
키워드
액체 제습기; 분무탑식 제습기; 모델링; 제습 공조; Liquid desiccant; Spray Tower; Modelling; Desiccant air conditioning