상세 보기
액체식 제습냉방 기반의 주거용 소형 공조시스템 개발 및 실험적 성능 평가
- 이재희;
- 동혜원;
- 조혜진;
- 이수진;
- 임려화;
- ... 정재원;
- 외 2명
초록
The purpose of this paper is to propose a small-scale heat-pump-driven liquid-desiccant (HPLD) air-conditioning system for residential buildings to remove both the sensible and latent loads. The operating strategies that can be applied to all seasons were established, and the operating performances and energy efficiencies of the proposed system were experimentally analyzed for the typical summer and winter operating modes. The proposed HPLD air-conditioning system consists of a liquid-desiccant (LD) unit for removing the latent load and a heat-pump (HP) unit for removing the sensible load. The experimental results indicated that the dehumidification rate was 5.29 kg/h, cooling capacity was 7450 W and its energy efficiency was 7.72 EER for the summer, and the humidification rate was 2.92 kg/h, heating capacity was 5075 W and its energy efficiency was 2.51 COP for the winter.
키워드
- 제목
- 액체식 제습냉방 기반의 주거용 소형 공조시스템 개발 및 실험적 성능 평가
- 제목 (타언어)
- Design and Performance Evaluation of Heat Pump-driven Liquid Desiccant Air-conditioning System for Residential Building
- 저자
- 이재희; 동혜원; 조혜진; 이수진; 임려화; 김보선; 배홍근; 정재원
- 발행일
- 2020-11
- 유형
- Proceeding
- 저널명
- 대한설비공학회 2020 동계학술발표대회 논문집
- 페이지
- 59 ~ 62