Low-tube-voltage CT urography using low-concentration-iodine contrast media and iterative reconstruction: A multi-institutional randomized controlled trial for comparison with conventional CT urography

  • Kim, S.Y.; 
  • Cho, J.Y.; 
  • Lee, J.; 
  • Hwang, S.I.; 
  • Moon, M.H.; 
  • ... Kim, Yong Soo; 
  • 외 15명
Citations

WEB OF SCIENCE

22
Citations

SCOPUS

24

초록

Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced. © 2018 The Korean Society of Radiology.

키워드

Computed tomography; Contrast media; Double dose reduction; Low dose; Urography; iodinated contrast medium; iodine; iohexol; contrast medium; adult; Article; body mass; comparative study; computer assisted tomography; contrast enhancement; contrast to noise ratio; controlled study; diagnostic test accuracy study; figure of merit; human; image quality; image reconstruction; major clinical study; middle aged; osmolality; prospective study; radiation dose; randomized controlled trial; risk factor; sensitivity and specificity; signal noise ratio; urinary tract; urography; aged; chemistry; computer assisted diagnosis; devices; diagnostic imaging; female; male; procedures; urography; x-ray computed tomography; young adult; Adult; Aged; Contrast Media; Female; Humans; Image Interpretation, Computer-Assisted; Iodine; Male; Middle Aged; Prospective Studies; Signal-To-Noise Ratio; Tomography, X-Ray Computed; Urinary Tract; Urography; Young Adult
제목
Low-tube-voltage CT urography using low-concentration-iodine contrast media and iterative reconstruction: A multi-institutional randomized controlled trial for comparison with conventional CT urography
저자
Kim, S.Y.; Cho, J.Y.; Lee, J.; Hwang, S.I.; Moon, M.H.; Lee, E.J.; Hong, S.S.; Kim, C.K.; Kim, K.A.; Park, S.B.; Sung, D.J.; Kim, Yong Soo; Kim, Y.M.; Jung, S.I.; Rha, S.E.; Kim, D.W.; Lee, H.; Shim, Y.; Hwang, I.; Woo, S.; Choi, H.J.
DOI
10.3348/kjr.2018.19.6.1119
발행일
2018-00
유형
Article
저널명
Korean Journal of Radiology
권
19
호
6
페이지
1119 ~ 1129

파일 다운로드

Thumbnail