Low-tube-voltage CT urography using low-concentration-iodine contrast media and iterative reconstruction: A multi-institutional randomized controlled trial for comparison with conventional CT urography

  • Kim, S.Y.
  • Cho, J.Y.
  • Lee, J.
  • Hwang, S.I.
  • Moon, M.H.
  • ... Kim, Yong Soo
  • 외 15명
Citations

WEB OF SCIENCE

22
Citations

SCOPUS

24

초록

Objective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced. © 2018 The Korean Society of Radiology.

키워드

Computed tomographyContrast mediaDouble dose reductionLow doseUrographyiodinated contrast mediumiodineiohexolcontrast mediumadultArticlebody masscomparative studycomputer assisted tomographycontrast enhancementcontrast to noise ratiocontrolled studydiagnostic test accuracy studyfigure of merithumanimage qualityimage reconstructionmajor clinical studymiddle agedosmolalityprospective studyradiation doserandomized controlled trialrisk factorsensitivity and specificitysignal noise ratiourinary tracturographyagedchemistrycomputer assisted diagnosisdevicesdiagnostic imagingfemalemaleproceduresurographyx-ray computed tomographyyoung adultAdultAgedContrast MediaFemaleHumansImage Interpretation, Computer-AssistedIodineMaleMiddle AgedProspective StudiesSignal-To-Noise RatioTomography, X-Ray ComputedUrinary TractUrographyYoung Adult
제목
Low-tube-voltage CT urography using low-concentration-iodine contrast media and iterative reconstruction: A multi-institutional randomized controlled trial for comparison with conventional CT urography
저자
Kim, S.Y.Cho, J.Y.Lee, J.Hwang, S.I.Moon, M.H.Lee, E.J.Hong, S.S.Kim, C.K.Kim, K.A.Park, S.B.Sung, D.J.Kim, Yong SooKim, Y.M.Jung, S.I.Rha, S.E.Kim, D.W.Lee, H.Shim, Y.Hwang, I.Woo, S.Choi, H.J.
DOI
10.3348/kjr.2018.19.6.1119
발행일
2018-00
유형
Article
저널명
Korean Journal of Radiology
19
6
페이지
1119 ~ 1129

파일 다운로드