초록

It is necessary to obtain a fire resistance certification in order to use Fire Protection Coating in Korea. According to the fire test standards, columns have four heating sides and beams have three. In comparison with columns which are heated four sides equally, beams have three exposed sides and one unexposed up side. So the question arises as to there were the differences between the temperature of up side and others of beams in fire test. The purpose of this study is to consider the positions of thermocouples for beams through a comparative analysis of the temperature data obtained from fire certification tests.