상세 보기
초록
It is necessary to obtain a fire resistance certification in order to use Fire Protection Coating in Korea. According to the fire test standards, columns have four heating sides and beams have three. In comparison with columns which are heated four sides equally, beams have three exposed sides and one unexposed up side. So the question arises as to there were the differences between the temperature of up side and others of beams in fire test. The purpose of this study is to consider the positions of thermocouples for beams through a comparative analysis of the temperature data obtained from fire certification tests.
키워드
Fire protection coating; Fire resistance; Fire test; Steel beam; Unexposed heating side
- 제목
- 강재보용 내화피복의 내화성능 평가단면에 대한 고찰
- 제목 (타언어)
- Review on Fire Test Section of Fire Protection Coating for Steel Beam
- 저자
- 전수민; 김재준
- 발행일
- 2016-04
- 저널명
- 한국화재소방학회 논문지
- 권
- 30
- 호
- 2
- 페이지
- 49 ~ 55