비내진상세를 가진 2층 R/C골조의 내부 철골프레임 및 벽체형 마찰댐퍼 보강효과

Strengthening effect of Non-Seismic detailed Two-story Reinforced Concrete Frame retrofitted with H-steel and Wall Friction Damper

초록

The purpose of this study is to confirm the Strengthening Effect of Non-Seismic detailed Reinforce Concrete Frame Retrofitted with H-steel and the Wall Friction Damper of 200kN capacity. In order to confirm this strengthening effect, the specimens were designed referring to the standard drawings of school in 1980 and the size is 4.35m×6.95m considering the laboratory conditions. The test parameters were set as Bare Frame(OMF-B) and two stories Retrofitted with H-steel and Wall Friction Damper Frame(OMF-HW). As a test method, Static Cyclic Loading test conducted for the lateral load. As a result, the improved performance at the maximum force and displacement is confirmed.

키워드

내진보강철근콘크리트 골조마찰댐퍼보강효과Seismic RetrofitReinforced Concrete FrameFriction DamperStrengthening Effect
제목
비내진상세를 가진 2층 R/C골조의 내부 철골프레임 및 벽체형 마찰댐퍼 보강효과
제목 (타언어)
Strengthening effect of Non-Seismic detailed Two-story Reinforced Concrete Frame retrofitted with H-steel and Wall Friction Damper
저자
전형준배백일최창식
발행일
2019-10
유형
Proceeding
저널명
대한건축학회 2019년도 추계학술발표대회논문집
39
2
페이지
431 ~ 432